Home Print this page Email this page Users Online: 382
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 26  |  Issue : 1  |  Page : 72-76

Thermometry: A simple objective method for burn depth assessment


1 Department of Surgery, Plastic Surgery Unit, NSCB Government Medical College, Jabalpur, Madhya Pradesh, India
2 Department of Surgery, NSCB Government Medical College, Jabalpur, Madhya Pradesh, India
3 Department of Pathology, NSCB Government Medical College, Jabalpur, Madhya Pradesh, India

Correspondence Address:
Prof. Pawan Agarwal
292/293, Napier Town, Jabalpur - 482 003, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijb.ijb_19_18

Rights and Permissions

Introduction: Accurate assessment of burn wound depth is important because it determines the choice of treatment and prognosis. Clinical evaluation remains the most commonly used modality with its accuracy varies from 50% to 70%. This study was conducted to assess the accuracy and feasibility of burn wound depth using noninvasive noncontact technique using infrared thermometry. Materials and Methods: Fifteen patients' burn wounds depth was classified clinically into full-thickness, deep partial-thickness, or superficial partial-thickness burns. Thermometry was performed on 3rd day of burn injury using the handheld infrared thermometer. A punch biopsy was taken from all three areas (deep, deep-partial, and superficial-partial burns). A correlation between surface temperature and depth of burn by histopathology was done. Results: 12/15 patients total burn surface area (TBSA < 65%) survived and three patients (TBSA > 65%) died. In 11/12survivors, thermometry correctly predicted final burn depth. One of 12 burns superficial burn was wrongly assessed clinically as full thickness but was correctly classified by thermometry and healed within 21 days without surgery. 3/12 burns on clinical assessment thought to be superficial were deep; two were correctly predicted by thermometry. Conclusions: Handheld infrared thermometer can be used in conjunction with clinical examination to improve the efficacy of burn wound depth assessment.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed288    
    Printed30    
    Emailed0    
    PDF Downloaded14    
    Comments [Add]    

Recommend this journal